孙超,刘景波,张昊天,袁哲,王跃,尹燕杰,刚宏林.开塞露(含甘油)含量测定方法的改进[J].中国药品标准,2017,18(4):275-278 |
开塞露(含甘油)含量测定方法的改进 |
Improvement of Determination for Glycerol Enema |
投稿时间:2017-03-29 修订日期:2017-08-08 |
DOI: |
中文关键词: 开塞露(含甘油) 含量测定 方法改进 |
英文关键词: Glycerol Enema Determination Improvement |
基金项目: |
|
摘要点击次数: 706 |
全文下载次数: 142 |
中文摘要: |
目的:对开塞露(含甘油)含量测定方法进行改进。方法:改变样品的取样量,按国家药品标准WS1-XG-018-2011对不同厂家的开塞露(含甘油)进行含量测定。结果:样品的取样量在0.10g~0.19g之间,反应完全,滴定结果准确,重现性好。结论:改进方法后,能更准确的测定甘油的含量,建议修改原标准。 |
英文摘要: |
Objective: To improve the method for the determination of enema in Glycerol Enema. Methods:Via changing the sampling volume, and combined with the dose-response relationship of sample and reagent volume, in accordance with the national drug standard WS1-XG-018-2011 test method for determination, several batches of Glycerol Enema from different manufacturers were determined. Results: When the sample volume is from 0.10g to 0.19g, the reaction will achieve complete response, the titration results are accurate and the reproducibility is good. Conclusion: It is more accurate to determine the content of glycerol after reducing the amount of sample. The original standard should be revised. |